Leaking Lakewood Water Heater Pressure Relief Valve

Posted by on Dec 9, 2014 in Gas Water Heater Repair Lakewood CO, Water Heater Repair Lakewood CO

The pressure relief valve of a water heater has an essential job – seeing to it the water heater tank does not explode. So with that in mind, Water Heater Repair Lakewood CO wishes to make certain house owners are aware of the best ways to best look after it. They will certainly leak when the valve breaks or when the water storage tank pressure gets greater then the relief point.Hot Water Heater Repair Lakewood CO

We suggest that at least two times a year, homeowners test to make sure the pressure relief valve, or T&P valve as we will call it, is working appropriately. All one needs to do is raise the handle for a few seconds and let go of it. It must snap back to its initial position. When it is lifted, one might hear the noise of pressure being released , much like the noise of air coming out of a tire pump when being disconnected. Also, a little water might come out too. Both are normal. If the valve has not been tested for a number of years, it may stick at first too.

Nevertheless, if the handle does not snap back, or if it continues to leak a little water, that is not typical. If it still leaks some, raise the handle a couple of more times to see if it will re-seat itself. You could wish to wait a day or so it see if it re-seats itself prior to presuming it needs to be changed.

Hot Water Heater Repair Lakewood CO would prefer to deal with any T&P valve replacements for you, so though hot water heaters are generally fairly maintenance free, there are some safety precautions one need to bear in mind. With that in mind here is an overview of a pressure relief valve replacement.

1. The gas to the water heater needs to be shut off, or the breaker for an electrical water heater.
2. The cold water cut-off valve needs to be closed next.
3. The valve below the T&P valve needs to be opened to drain some water in order to relieve some of the pressure in the storage tank.
4. The overflow pipe of the T&P valve has to be removed. It may need to be cut off if it is soldered or firmly glued.
5. The pressure relief valve has to be unscrewed with a pipe wrench.
6. Wrap the brand-new T&P valve with Teflon tape and screw it back in place. Make certain the overflow pipe opening is positioned away from the storage tank.
7. Reattach the drain pipe, likewise making use of new Teflon tape.
8. Turn the water back on, and analyze your work for any leaks.

The following video gives an overview of this procedure: